RF Tuning Range (via software) |
118.6 MHz |
TX/RX Duplex Frequency Separation |
252.04 MHz |
Supported Configurations |
1+0 / 1+1 HSB / 1+1 SD / 1+1 FD / 2+0 |
Modulation Schemes |
128 BCM |
Supported Capacities |
STM-1 / 2xSTM-1 / 3xSTM-1 / 4xSTM-1 / STM-4 |
Demodulation |
Coherent (fully digital) |
Output Power at Point C’: |
Standard Version (dBm) |
STM-1
(128 BCM) |
2xSTM-1 / 4xSTM-1 / STM-4(128 BCM) |
+ 23 |
Note 1 |
High Power Version (dBm) |
+ 26 |
Note 1 |
Receiver Sensitivity at BER 10³ at point C
(1+0 conf., RF filter losses included)
Rx Power (dBm) |
- 72 |
Note 1 |
Frequency Stability |
± 5 ppm |
ATPC |
20 dB range implemented in 1 dB steps |
RTPC |
up to 40 dB in 1 dB steps, software programmable |
Tributary Interfaces |
Electrical / Optical STM-1
Optical STM-4
Fast / Gigabit Ethernet
63xE1 |
Service Channels |
1x2 Mbit/s wayside channel per STM-1 (maximum 2)
1xV.11 64 Kbit/s |
IDU/ODU Interconnection (per terminal) |
One 50 _ Coaxial Cable per RT
N-type connectors |
Power Supply |
48 Vdc (– 15%, + 20%) |
Power Consumption (per Terminal) |
65 W in 1+0 configuration
110 W in 1+1 configuration |
Environmental Performance |
ODU Weather Proofing Class |
IP65 |
IDU Temperature Range |
- 5 °C to + 50 °C |
ODU Temperature Range |
- 35 °C to + 55 °C |
Compliant with |
ETSI EN 302 217 |